BASIC INFO

Yokogawa ZR402G-T-E-E-A/SCT/H ZR402G Zirconia Oxygen Analyzer Converter




 


 

General Introduction of Yokogawa ZR402G-T-E-E-A/SCT/H ZR402G Zirconia Oxygen Analyzer Converter
 
Yokogawa ZR402G zirconia oxygen analyzer converter works with separate type zirconia oxygen probe detector ZR22G and ZR22S, it's a panel mounted type which only available installed in safe zones, accept signals from sensor and output digital and contact signals to monitoring and control room.



Yokogawa ZR402G-T-E-E-A/SCT/H ZR402G Zirconia Oxygen Analyzer Converter

Yokogawa's zirconia oxygen analyzers are used for combustion monitoring and control in a wide variety of applications and help industries to make considerable achievements in energy saving. The applications range from energy-consuming industries, such as iron and steel, electric power, oil and petrochemical, ceramics, pulp and paper, food, and textiles, to various combustion facilities, such as incinerators and small- and medium sized boilers. Combustion monitoring and control using the analyzer also contribute to a lowering of CO2, SOx, and NOx emissions by allowing for more complete combustion, thus preventing global warming and air pollution.

 

The ZR402G converter is equipped with an LCD touch screen which has various setting displays, a calibration display, oxygen concentration trend display, with easier operation and improvement of display functions. The converter is equipped with various standard functions such as measurement and calculation as well as maintenance functions including self-test. The ZR22G separate-type detector uses a high-reliability zirconia sensor, and its heater assembly can be replaced on site. The detector is mounted, for example, on the wall of a flue and can measure the gases directly. The ZR22S separate-type detector for explosion-proof applications is also available.

 

Features of Yokogawa ZR402G-T-E-E-A/SCT/H ZR402G Zirconia Oxygen Analyzer Converter

 

· The separate type converter ZR402G incorporates a LCD touchscreen for ease of operation.

· The built-in heater assembly of the probe can be replaced on site, reducing maintenance costs (ZR22G only).

· The probe uses a long-life, high-reliability, field replacable Zirconia sensor.

· Remote maintenance using digital communications (HART) reduces maintenance costs.

Note: HART is a registered trademark of HART Communication Foundation.

 

Specification of Yokogawa ZR402G-T-E-E-A/SCT/H ZR402G Zirconia Oxygen Analyzer Converter

 

Measurement object

Oxygen concentration in combustion exhaust gas and mixed gas

Measurement system

Zirconium oxide sensor

Measurement range

0.01 to 100 vol% O2

Output signal

4 to 20 mA DC, two points (ZR402G) (maximum load resistance 550Ω)

Setting range

Any setting in the range of 0 - 5 vol%O2 to 0 - 100 vol%O2 (in 1 vol% O2), or partial range

Digital communication (HART)

250 to 550Ω, depending on number of field devices connected to the loop (multi-drop mode)

Sample gas pressure

-5 to +250 kPa (Pressure compensation option necessary over +5 kPa)

Sample gas temperature

0 to 700℃ (Probe only)
700 to 1871℃ (with 0.15m probe with JIS 5K 32 FF flange and ZR22P High Temperature Probe Adapter)

Probe length

0.15, 0.4, 0.7, 1.0, 1.5, 2.0, 2.5, 3.0, 3.6, 4.2, 4.8, 5.4 m

Contact output

Four points (one is fail-safe, normally open)

Contact input

Two points

Calibration

Method; zero/span calibration
Calibration mode; automatic, semi-automatic and manual (with an LCD touchscreen)

Construction of detector (ZR22G)

Heater and thermocouple replaceable construction. 
Non-explosion-proof. Equivalent to NEMA4X/IP66

Construction of converter (ZR402G)

Non-explosion-proof, outdoor installation, equivalent to NEMA4X/IP66

Ambient Temperature

Probe (ZR22G): -20 to 150℃
Converter (ZR402G): -20 to 55℃)

Reference Gas System

Instrument Air (preferred): 50 kPa (200 kPa with check valve) + the pressure inside the furnace; Approx. 1 Nl/min consumption

Natural convection

Power supply

85 to 264 V AC; 45 to 66 Hz


Performance of Yokogawa ZR402G-T-E-E-A/SCT/H ZR402G Zirconia Oxygen Analyzer Converter

 

Repeatability

±0.5% Maximum value of set range

Linearity

±1% Maximum value of set range

Drift

±2% Maximum value of set range/month

Response time (T90)

90% response within 5 sec (60 sec for explosion-proof ZR22S)

 


General Specification of Yokogawa ZR402G-T-E-E-A/SCT/H ZR402G Zirconia Oxygen Analyzer Converter
 

Main Characters

Description

Display

LCD display of size 320 by 240 dot with touchscreen

Output Signal

4 to 20 mA DC, two points

Contact Output Signal

Four points (one is fail-safe, normally   open)

Contact Input

Two points

Ambient Temperature

-20 to +55°C

Power Supply Voltage

100 to 240 V AC

Maximum Distance between Detector and Converter

300 m or less

Construction

Outdoor installation, NEMA 4X/IP66

Wiring Connection

G1/2, Pg 13.5, M20 × 1.5, 1/2NPT

Functions

Display, Auto Calibration, Blowback, and  etc

 

Model and Suffix Codes of Yokogawa ZR402G-T-E-E-A/SCT/H ZR402G Zirconia Oxygen Analyzer Converter
 

Model

Suffix Codes

Description

ZR402G

         

Separate type Zirconia Oxygen   Analyzer, Converter

Converter thread

-P

       

G1/2

-G

       

Pg13.5

-M

       

M20x1.5

-T

       

1/2NPT

Display

 

-J

     

Japanese

 

-E

     

English

 

-G

     

German

 

-F

     

French

 

-C

     

Chinese

Instruction manual

   

-J

   

Japanese

   

-E

   

English

   

-C

   

Chinese

--

     

-A

 

Always -A

Options

       

/HS

Set for Humidity Analyzer

       

/H

Hood

       

/SCT

Stainless steel tag plate

       

/PT

Printed tag plate

       

/C2

NAMUR NE43 Failure alarm down-scale

       

/C3

NAMUR NE43 Failure alarm up-scale

       

/EQ

EAC with PA

       

/ER

EAC




Ordering Models of Yokogawa ZR402G-T-E-E-A/SCT/H ZR402G Zirconia Oxygen Analyzer Converter
 
ZR402G-P-E-E-A,ZR402G-G-E-E-A,ZR402G-M-E-E-A,ZR402G-T-E-E-A
ZR402G-P-E-E-A/SCT,ZR402G-G-E-E-A/SCT,ZR402G-M-E-E-A/SCT,ZR402G-T-E-E-A/SCT
ZR402G-P-E-E-A/C2,ZR402G-G-E-E-A/C2,ZR402G-M-E-E-A/C2,ZR402G-T-E-E-A/C2
ZR402G-P-E-E-A/C3,ZR402G-G-E-E-A/C3,ZR402G-M-E-E-A/C3,ZR402G-T-E-E-A/C3
ZR402G-P-E-E-A/HS,ZR402G-G-E-E-A/HS,ZR402G-M-E-E-A/HS,ZR402G-T-E-E-A/HS
ZR402G-P-E-E-A/PT,ZR402G-G-E-E-A/PT,ZR402G-M-E-E-A/PT,ZR402G-T-E-E-A/PT
ZR402G-P-E-E-A/H/SCT,ZR402G-G-E-E-A/H/SCT,ZR402G-M-E-E-A/H/SCT,ZR402G-T-E-E-A/H/SCT
ZR402G-P-E-E-A/SCT/C3,ZR402G-G-E-E-A/SCT/C3,ZR402G-M-E-E-A/SCT/C3,ZR402G-T-E-E-A/SCT/C3
 

We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.

We mainly supply Yokogawa, Emerson, Rosemount, Fisher, Honeywell, Siemens, ABB, FLUKE, Endress+Hauser, Schneider Electric, Pepperl+Fuchs, MTL, Rockwell(Allen Bradley), Hirschmann, Eaton, Moeller, FUJI, Omron, Yaskawa, Norgren, CHINT, Hach, Weidmuller, Phoenix, SMC, Testo, ASCO, Parker, Mitsubishi, Festo, GE, CISCO, Auma, IFM, GM, Turck, Bently Nevada, MOXA, Krohne, Foxboro and so on.
 
 
Why choose us?
 
1. 100% original product, 100% quality assurance.
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
 
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
 
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.
 
Packaging: 
Imported with original packaging or standard export packing.Customize design is acceptable.
 
Contact:
 
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat) 